Call to us +34623 541 934

Close (x)

Call to us +34623 541 934

Close (x)
×
    Air Conditioning Cassette 90x90 Haier Health Connect 140 Trif.

    ¿Any doubt about the product?

    Talk to us and consult us. We will solve all your doubts

    Air Conditioning Cassette Haier Round-Flow 140 Trif. AB140S2SR1FA(H) + 1U140S2SN2FB

    Referencia: HAIROUNDCAS140THC
    €2,058.32 
    Tax included

    IMMEDIATE DELIVERY!

    For deliveries in Europe, consult delivery time

    Envío GRATIS en España (Península) a partir de 300€ + info

    Email has been sent successfully.

    Calcular Gastos de Envío
    🛡️ Pago Seguro ✅ Garantía Oficial

    Cassette Haier AB140S2SR1FA(H) + 1U140S2SN2FB

    Round-Flow 140 Triphasic - Absolute Industrial Power

    Cassette Haier Round-Flow 140 Classic - Total industrial power cassette air conditioning system with 8-way Round-Flow technology and maximum stability three-phase feeding, ideal for the largest industrial facilities up to 140m2. Circular air distribution with integrated Wi-Fi and maximum triphase power available.
    13.4 kW
    Cold power
    15.0 kW
    Power Calor
    2,43
    EER
    A+/A++
    Energy Label
    34 dBA
    Sound level
    10.0 A
    Triphase Intensity
    ️ Round-Flow Wi-Fi Integrated UVC Sterilization R32 Ecological 8 8 Independent roads Industrial Use Triphasic 380V Panel 950mm

    Full model: Indoor Unit AB140S2SR1FA(H) + Outdoor Unit 1U140S2SN2FB

    Series: Round-Flow - Circular distribution technology with 8 independent tracks

    Application: Ideal for the largest industrial facilities up to 140m2

    Panel: PB-950QB(H) 950×950mm removable in false ceiling

    Trinity Absolute Power: 13,4kW with only 10,0A intensity

    ▪ Advantages Absolute Power 380V

    Absolute Power:
    13,4kW maximum in Round-Flow
    Stable Intensity:
    10,0A balanced operation
    Arranque Suave:
    Only 2.0A vs 5.0A monophasic
    Maximum Capacity:
    140m2 total coverage
     

    Security policy

     

    Delivery policy

     

    Refund policy

    I'M NOT SURE I'M READY FOR THIS

    The Maximum Absolute Power for High Demand Industrial Installations

    MODEL: AB140S2SR1FA(H) + 1U140S2SN2FB

    ▪ TECHNICAL SPECIFICATIONS OF MOST POTENCE

    EXTREMATIVE CAPACITY

    • Refrigeration power: 14.0 kW (12.020 kcal/h)
    • Heating power: 15.5 kW (13,330 kcal/h)
    • Maximum coverage: Up to 140 m2 industrial
    • Ideal application: Large ships, industrial complexes

    ▪ OPTIMIZED TRIFÁSICA ALIMENTATION

    • Tension: 380-415V triphase
    • Ultra Low Intensity: 11,5A (vs 32,0A monophasic)
    • Arranque Suave: 2.5A (vs 5,0A monophasic)
    • Electrical Saving: 64% less intensity

    ️ Indoor Unit ROUND-FLOW - REVOLUTION TECHNOLOGY

    8-WAY DISTRIBUTION SYSTEM

    The exclusive Round-Flow technology Haier provides a fully uniform 360° air distribution through 8 independent outputs, eliminating dead areas and ensuring a homogeneous temperature throughout the industrial facility.

    Đ DIFERENCEL SALE: +23% more airflow vs. traditional 4-way cassettes

    SPECIFICATIONVALUEBENEFICIO
    Air flow rate2100/1900/1650/1400 m3/h4 speeds for maximum flexibility
    Sound level36/34 dB(A)Ultra silent for industrial use
    Dimensions840×840×245 mmCompact design for false ceiling
    Weight24/31 kgStandard installation/with pump
    Front Panel950×950 mmDiscreet and elegant design

    INDUSTRIAL APPLICATIONS OF MEXICO

    GREAT COMPLEJES

    Extensive industrial ships, logistics centers, production plants that require maximum power and electrical stability.

    TECHNICAL INSTALATIONS

    Large-surface laboratories, research centers, specialized technical workshops with triphase feeding.

    DATA CENTRES

    Large-capacity server rooms, processing centers that need constant and efficient cooling.

    MÁXIMA POTENCIA INDUSTRIAL GARANTIZED

    The 140 Triphasic model represents the summit of the Round-Flow range for high demand industrial installations

    🏭 Outdoor Unit TRIFÁSICA - MÁXIMA POTENCIA INDUSTRIAL

    ▪ EXCLUSIVE VENTATIVES OF TRIFASIC ALIMENTATION

    Ultra Optimized Intensity: 11,5A vs 32,0A monophasic (64% less)

    Arrange Ultra Suave: 2.5A vs 5.0A monophasic (50% less)

    :️ Perfect Balance: Stable and constant triphase distribution

    Optimized cabling: 5 x 6.0 mm2 for maximum safety

    TECHNICAL SPECIFICVALUE TRIFÁSICOINDUSTRIAL SALE
    Electrical supply380-415V ~ 3N 50HzCompatible with industrial networks
    Nominal intensity11,5A64% less monophasic vs
    Corriente de Arranque2.5ASoft opening without spikes
    External dimensions1050×760×330 mmCompact design robust
    Weight of Unit68.0 kgRobust industrial construction
    Operating range-15°C to +50°CExtreme secured operation

    ENERGY EFFECTIVE EFFICIENCY

    ENERGY CLASIFICATION

    A++

    SEER: 6,10 (Refrigeration)
    SCOP: 4,80 (Calfaction)

    ANNUAL CONSURE

    813 kWh/year

    Refrigeration: 813 kWh/a
    Heating: 3542 kWh/a

    AHORRO ECONOMIC GARANTIZED

    The maximum A++ energy efficiency of the 140 Triphasic model, combined with the advantages of triphasic feeding, ensures an energy saving of 30-40% compared to conventional systems, with an estimated 2-3-year ROI in intensive industrial facilities.

    INDUSTRIAL ADVANCEMENTS

    CONTROL INTELIGENTE Wi-Fi hOn

    Wi-Fi control system integrated with hOn app for complete remote management, smart programming, consumption monitoring and real-time diagnostics.

    UVC (OPCIONAL)

    Optional UVC system that eliminates 99.9% of viruses and bacteria, ideal for industrial environments that require maximum air hygiene.

    ️ REFRIGERANT R32 ECOLOGICO

    Refrigerant Gas Last-generation R32 with 2.20 kg of load, 68% less global warming potential vs R410A. Optimized load for maximum performance.

    DRENAJE BOMBA INCLUDED

    Factory integrated drainage pump for installations without natural unevenness, elevation up to 750mm, maximum industrial installation flexibility.

    ️ INTELIGENT AUTODIAGNÓSTICO

    Advanced autodiagnosis system that automatically detects and reports any anomaly, minimizing stop times in critical facilities.

    ️ EXTREME FUND

    Operation guaranteed from -15°C to +50°C, resistance to extreme industrial conditions, 24/7 operation without limitations.

    TRIFASIC SPECIFICATIONS

    ▪ SPECIFIC REQUIREMENTS

    ALIMENTATION
    380-415V ~ 3N 50Hz

    CABLE
    5 x 6.0 mm2

    PROTECTION
    Difference 30mA

    MAGNETOTÉRMICO
    25A Curva C

    ▼ VENTATIONS OF TRIFASIC INSTALATION

    Model 140's three-phase facilities allow perfect integration with existing industrial infrastructures, significantly reducing electrical intensity and ensuring stable and efficient operation 24 hours a day.

    ROUND-FLOW 140 TRIFÁSICO: INDUSTRIAL TECHNOLOGY

    Maximum power, maximum efficiency, maximum electrical stability. The 140 Triphasic model represents the definitive solution for industrial installations that do not support performance and reliability commitments.

    YOU'VE GOT A LOT OF MONEY ON YOUR OWN!

    Haier Round-Flow 140 Triphasic - The Definitive Solution for Large Installations

    ▪ EXCLUSIVE TRIFASTIC VENTAGES

    • 64% LESS Intensity: 11,5A vs 32,0A monophasic
    • Arrange Ultra Suave: No stream peaks
    • Stability 24/7: Continuous industrial operation
    • Perfect integration: With existing three-phase infrastructures

    GARANTIZED RENTABILITY

    • Efficiency A++: SEER 6,10 / SCOP 4,80
    • 30-40% Energy Saving: vs. conventional systems
    • ROI 2-3 years: Industrial facilities
    • Reduction of Electrical costs: Ultra optimized intensity

    ️ SUPERIOR TECHNOLOGY

    • Round-Flow 8 Ways: +23% more airflow
    • Control Wi-Fi hOn: Remote smart management
    • Ultra Silence: From 34 dB(A)
    • Refrigerant Gas R32: Maximum environmental respect

    IDEAL IMPLICATIONS OF MODEL 140 TRIFÁSICO

    GREAT NAVES

    Logistics centers, production plants, industrial warehouses up to 140m2

    LABORATORY

    Research centers, technical laboratories, scientific facilities

    DATA CENTRES

    Server rooms, processing centers, critical IT infrastructures

    INDUSTRIA PESADA

    Industrial workshops, factories, advanced manufacturing facilities

    WHERE IS THE ROUND-FLOW 140 TRIFÁSICO?

    SPA_LATN THE ABSOLUTE LEADER

    The maximum power in triphasic round-flow cassette. Exclusive 8-way technology independent.

    √ ROBUSTEZ INDUSTRIAL

    Designed for 24/7 operation in extreme conditions. Guaranteed resistance to industrial environments.

    ENVIRONMENTAL RESPECT

    Refrigerant Gas Last generation R32. 68% less environmental impact vs traditional refrigerants.

    FUTURE GARANTIZED

    Avant-garde technology with OTA updates. Future-proof investment for your company.

    PERSONALIZED INFORMATION AND BUDGET

    CONTACT DIRECTO

    Call us for specialized technical advice and installation calculation for your specific project.

    TECHNICAL BUDGET

    Personalized study of your industrial installation with ROI calculation and energy amortization.

    DISPONIBILITY

    Stock available for immediate delivery. Official guarantee Haier with specialized technical service.

    ▪ DON'T LET THIS TRADE OPORTUNITY GO!

    The Round-Flow 140 Triphasic is the smartest investment for industrial installations that seek maximum power, energy efficiency and uncompromising electrical stability.

    : MODEL: AB140S2SR1FA(H) + 1U140S2SN2FB

    The Round-Flow Industrial Technology Summit

    HAIROUNDCAS140THC

    Data sheet

    Brand
    Haier
    Indoor Unit
    AB140S2SR1FA(H)
    Outdoor Unit
    1U140S2SN2FB
    Panel
    PB-950QB(H)
    I send
    Infrarrojos YR-HQS01
    Color
    Blanco
    Refrigerant Gas
    R32
    Electrical supply
    Trifásica
    Recommended area (M2)
    Estancia de 120 a 135 m2
    Refrigerator capacity (W)
    13.400
    Refrigerator capacity (kcal / h)
    11.524
    Nominal consumption Cold (W)
    5.280
    Energy class (cold)
    A+
    SEER
    5,6
    Heat capacity (W)
    15.000
    Heat capacity (Kcal / h)
    12.900
    Nominal heat consumption (W)
    5.770
    Energy class (heat)
    A++
    SCOP
    4,8
    Minimum sound pressure UI DB
    34
    Dimensions u.i (anxfxh) mm
    840 x 840 x 288
    Dimensions u.e (anxfxh) mm
    950 x 370 x 965
    Weight Indoor Unit (Kg)
    32,0
    Weight Outdoor Unit (Kg)
    68,0
    Net weight (kg)
    97,5
    Diameter Liquid pipe
    3/8
    Diameter Gas Pipe
    5/8"
    Possibility Integration
    WiFi Included